Characteristic malfunctions
The most characteristic malfunction of accumulators  Seagate U8/.V8/.U10  is the spoiling (complete or partial) of contents of flesh - PZU. In this case the behavior of accumulator is absolutely not predicted. Was observed the following behavior of accumulators, caused by the partial spoiling of microprogram to flesh:
? accumulator started  1  time of  7-8  starting;
? during testing of surface accumulator "poured" a series of bed - blocks, a little "it slowed", and testing occurred further as if nothing were the matter. With povto rnom testing of this place bedy did not appear, but we could "be located" elsewhere;
? during testing of surface accumulator in the random place suddenly of klatsal with head, produced rekalibrovku and again continued testing. Surface defects were not detected;
? accumulator "rustled and howled" during an attempt at the testing.

The spoiling of contents of flesh - PZU it is caused by the gradual "runoff" of the injected charges, with the aid of which into flesh remain the data. Therefore we recommend even with correct contents of flesh - PZU to count and to write down it back into the accumulator.

Another frequently encountered malfunction, caused by the poor blocks of pitani 4, is the combustion of preamplifier - switchboard or servodekodera. In this case the accumulator does not leave into the readiness on  ATA,  accelerates the disk pack and emits sound similar to the "horse neigh".
For determining the precise reason for a similar malfunction, it is necessary to change the pay of accumulator for the deliberately proper. P ri this of flesh - PZU one should transpose to the pay - donor, having preliminarily verified the stability of its reading on the programmer. If "horse neigh" was preserved –camber preamplifier - switchboard, arranged inside the hermetically sealed-block. In this case the hermetically sealed-block is not subject to repairing.
If "neigh" disappeared –malfunction either in servodekodere on the pay - patient or was defective the choke of the nourishment of the preamplifier of switchboard.

Another variety of the malfunction of preamplifier - switchboard is the complete "silence" of accumulator during the supplying of nourishment. Moreover, if we unscrew screw in the region joint of hermetically sealed-block and to lay insulation spacer in order to exclude contact in the joint, then accumulator p ri to supply lead untwists engine. In this case hermetically sealed-bank it follows to recognize as unfit because of the spoiling of preamplifier - switchboard.

Sometimes are encountered accumulators without the surface defects, but of the periodically tapping by heads during testing specific parts of the disk space. In this case it is necessary to verify the binding of the microcircuit of the driver of engine  (èya002"8-.khkhkh)  and to replace, on it is guaranteed worker, microcircuit dual OU  l324.

本新闻共12页,当前在第10页  
01  02  03  04  05  06  07  08  09  10  
11  12  


上一篇:HRT的Seagate Drives U4英文说明书
下一篇:HRT的Seagate Drives U6英文说明书

  北京总部: 4006-505-808
  上 海 部: 021-58358765
  深 圳 部: 0755-83692929
  浙 江 部: 13666673722
  广 州 部: 020-83821091
  重 庆 部: 023-86870422
  昆 明 部: 15987117834
  哈尔滨部: 13946167430
  其它地区: 4006-505-808

经典案例
中国石油管理局-Oracle数据库恢
中国网通-IBM EXP300磁盘阵列数
大连鸿德经贸有限责任公司-SQL
中国地质环境监测院-HP LH3000
藁城市东街百货-EFS文件解密成
工商银行山东分行-AIX删除LV数
中央电视台新闻评论部-苹果分
promise乔鼎硬盘阵列数据恢复成
麒麟童文化-苹果分区无法打开,
NAS 8100服务器数据恢复成功 
解决方案
raid磁盘阵列OFFLINE后的应急方
磁盘未被格式化,是否格式化数据
误GHOST、误一键恢复灾难应急方
误删除、误格式化数据灾难应急
LINUX FSCK数据出错灾难应急方
北亚数据恢复 - 联系我们 - 关于北亚 - 友情链接 - 网站地图 - RSS聚合 
版权所有 北京北亚数据恢复中心
24小时免费咨询电话:4006-505-808 或 800-810-580
中关村部:北京市海淀区中关村大街11号E世界A座8层832B室
皂君庙部:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528室