您当前的位置:首页>>技术中心>>HRT技术文章>>正文
 
HRT的Seagate Drives U8, V8, U10英文说明书
作者: 来源: 日期:2006-3-26 1:49:16  点击次数:

Additional possibilities of the utility
Discharge  Smart- of the variables
After the repair of accumulator frequently appears the need for throwing out  Smart- variables and  Smart- the ravines  of the repaired disk, which contain info rmatsiyu, accumulated in the period of the operation of disk with the malfunction. For this follows vospol'zovat's 4 by point of menu  Actions - > Clear SMART.


Removal  Ata- the password
For the removal established  Ata- password it follows to use the point of the menu
Actions - > Unlock.


Resta RT of the accumulator
Sometimes can arise the need for perezagruzit' accumulator. In this case, if accumulator is found in the readiness on  Ata- to interface, it is possible to use point  Reset - > Super.  To accumulator will be fed the command of the complete reloading of mikroprog of rammy.


Work with  Vendor- by the region of the accumulator
In accumulators  Seagate U8/.V8/.U10  developers provided region for the "personal correspondence" of service engineers. This region, is more accurate, its first half, in no way it is used in the work of accumulator, but it is accessible che cut  Ata- interface and makes it possible to bring in all possible records. For example, in it it is possible to note the date of the entering of nakopitel 4 in the repair, the method of repair and the date of the beginning of warranty period. In guarantee elevation army accumulator, after reading these records (from the the very of nakopitel 4!)You can either refuse in the guarantee (if elapsed warranty period), or make conclusions about expediency and procedure of further repair.
Access to  Vendor- to region  is effected by means of menu  Actions - > Vendor Data.
Part  Vendor- of region, is located by 4 in its end itself, is overlapped modulus  Smart- of variables. Therefore to write in  Vendor- region is recommended only into its first half.
Debugging
In the process of work the utility, for the technological reasons, produces automatic changes in some parameters of accumulator. Therefore the interruption of the standard work of complex leads to all possible problems in the work as that:
? the impossibility of passport change, its discharge to the values on - to silence;
? hanging up upon the concealment of defects;
? the impossibility of access to  Smart- to monitoring;
? the incorrect determination of the logical parameters.

The most characteristic feature of the malfunction of the subsequent in view of nekor rektnoy work with the complex is the incorrect determination of the parameters of logical sect ditch: instead of standard value of  63  ravine sektora in the window of accumulator will be present another number. In this case one should act on the following algorithm:
11. Perezag to ruzit' the accumulator through point  Reset->.Super,  or by the disconnection of nourishment;
12. To remove from the accumulator the possible password through point  Actions - > Unlock;

本新闻共12页,当前在第11页  
01  02  03  04  05  06  07  08  09  10  
11  12  


上一篇:HRT的Seagate Drives U4英文说明书
下一篇:HRT的Seagate Drives U6英文说明书

  北京总部: 4006-505-808
  上 海 部: 021-58358765
  深 圳 部: 0755-83692929
  浙 江 部: 13666673722
  广 州 部: 020-83821091
  重 庆 部: 023-86870422
  昆 明 部: 15987117834
  哈尔滨部: 13946167430
  其它地区: 4006-505-808

经典案例
中国石油管理局-Oracle数据库恢
中国网通-IBM EXP300磁盘阵列数
大连鸿德经贸有限责任公司-SQL
中国地质环境监测院-HP LH3000
藁城市东街百货-EFS文件解密成
工商银行山东分行-AIX删除LV数
中央电视台新闻评论部-苹果分
promise乔鼎硬盘阵列数据恢复成
麒麟童文化-苹果分区无法打开,
NAS 8100服务器数据恢复成功 
解决方案
raid磁盘阵列OFFLINE后的应急方
磁盘未被格式化,是否格式化数据
误GHOST、误一键恢复灾难应急方
误删除、误格式化数据灾难应急
LINUX FSCK数据出错灾难应急方
北亚数据恢复 - 联系我们 - 关于北亚 - 友情链接 - 网站地图 - RSS聚合 
版权所有 北京北亚数据恢复中心
24小时免费咨询电话:4006-505-808 或 800-810-580
中关村部:北京市海淀区中关村大街11号E世界A座8层832B室
皂君庙部:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528室