The selection of the sheet, into which they hide defect, is produced in the window of tuning testirovani 4 in the list "Recovery type": ? "Upload" – to hide in P -.list; ? "One by one" – to hide in G -.list.
But one should remember that: 11) the concealment of sector in G -.list is produced more slowly than the concealment of sector in P -.list; 12) in G -.list it is possible to hide not more than 200 defects. Attempt at the concealment in G -.list of the large GO stake - VA of sectors on some piercings leads to the spoiling defect - sheets accumulator; 13) in G -.list it is not possible to hide some fatal defects to pove of rkhnosti, nap Reamer, caused by the spoiling of servometok on this track; 14) concealment in G -.list leads to the subsequent delay of linear reading / of record of data in this place for surface, which will be well noticeable on the test of flaw detector; 15) all concealments in G -.list of otob razhayutsya in Smart- counters of the acquired defects, whose nontrivial state can hinder subsequent sale of the repaired accumulator.
Therefore concealment in G -.list during the repair of accumulator is not recommended. By this procedure it is permissible of vospol'zovat's 4 only with the small stake - ve defects. In this case it is desirable after the placement of all obtained defects in G -.list, at the end of tests, to produce their transfer in P -.list by means of point Actions - > Merge defects G ->.p. After peremeshcheni of 4 defects should be produced pereformatirovaniye of surface. But as a whole, remember that the compartment into G -.list during the testing is not recommended. Correcting the passport If necessary of changing the name accumulator, or its logical razme of the Ra, it is possible to use the procedure of a change in the specifications of accumulator. In order to perform this operation, it is necessary to select the point of menu Service->.Special Area - > Change Passport. In this case on the screen the following dialogue will be given out: Field LBA count contains the volume of accumulator in LBA. Fields Size in this case will automatically show the new volume of accumulator in millions of bytes (precisely in them usually is measured volume producers), and also –in the megas-byte (precisely this value usually is shown BIOS). With the aid of fields Size you can monitor both the and other value. To the right on top, is arranged reference book. It is filled up on the basis of section [ LOGICAL ] file SConner..ini. Its use frees you from the memorization of constants. You can introduce there standard models and it is simple to select them. Dual flick in the line of list will transfer data from it into the fields of introduction. 上一篇:HRT的Seagate Drives U4英文说明书 下一篇:HRT的Seagate Drives U6英文说明书 |