您当前的位置:首页>>技术中心>>HRT技术文章>>正文
 
HRT的Seagate Drives U8, V8, U10英文说明书
作者: 来源: 日期:2006-3-26 1:49:16  点击次数:

Pressure on knob  OK  will carry from the edited parameters into the accumulator. On knob  Cancel,  you can forego the introduction of changes.

Remember that in the accumulators with the volume of more than  8  Gbayt field  Cyl  cannot exceed value  of 16384.  In this case the actual size of accumulator is determined by field  LBA count.  Therefore,  with the filling of the fields of accumulator with the volume of more than  8  Gbayt with the latter must be filled up field  LBA count!


When it is desired to return accumulator to the parameters, established for this disk at the plant, it is possible to use the point of menu  Service->.Special Area->.Restore Passport.
Correcting passport should be produced after the concealment of all defects on pove of rkhnosti, since during the procedure of the concealment of defects is produced the discharge Pa of rametrov of passport to avoid interference of ac
Work from flesh - by memory
On accumulators  Seagate U8/.V8/.U10  are established flesh - PZU, in which is written down the starting microprogram of accumulator.
No other microprogram (for example imer, mask PZU in OEVM of disk) on accumulators  Seagate U8/.V8/.U10  it is provided.  In view of this, the loss of microprogram into flesh - PZU will lead disk into the completely inefficient state. In this case will have to unsolder microcircuit PZU from the pay and to pierce on the programmer.
The means of contained PZU, counted through ATA- interface and means, poured in PZU on the programmer, they are distinguished by the transposition of the bits of data.

From the aforesaid it follows that work from flesh - PZU of accumulators  Seagate U8/.V8/.U10  one should extremely ostor ozhno.  Do not attempt to flood into the accumulator unknown piercing and do not turn off the nourishment of accumulator during the programming by the accumulator of your of flesh - PZU.

One of the most extended malfunctions of accumulators  Seagate U8/.V8/.U10  is the partial spoiling of mik of roprogrammy. In this case flesh - PZU can either unstably read several cells, each time reading of them another value or it is observed the stable readout of incorrect information. Unfortunately, developers  Seagate U8/.V8/.U10  did not provide procedure to samotesti rovaniya of contained PZU with the start of accumulator, and this malfunction with accumulator itself is in no way revealed. In view said, during the repair it is extremely desirable to flood in PZU of accumulator guaranteed working microprogram with the number of version,  which completely coincides  with the version PZU of the overhauled accumulator.

At the worst, in the absence of the file of resources with the necessary version of piercing and observing unstable reading of flesh - PZU, it is possible to attempt vospol'zovat's 4 by following procedure:
4) to count as much as possible once of flesh - PZU of accumulator in the different files. Rekomenduyets 4 to count not less than  1 0  times;

本新闻共12页,当前在第05页  
01  02  03  04  05  06  07  08  09  10  
11  12  


上一篇:HRT的Seagate Drives U4英文说明书
下一篇:HRT的Seagate Drives U6英文说明书

  北京总部: 4006-505-808
  上 海 部: 021-58358765
  深 圳 部: 0755-83692929
  浙 江 部: 13666673722
  广 州 部: 020-83821091
  重 庆 部: 023-86870422
  昆 明 部: 15987117834
  哈尔滨部: 13946167430
  其它地区: 4006-505-808

经典案例
中国石油管理局-Oracle数据库恢
中国网通-IBM EXP300磁盘阵列数
大连鸿德经贸有限责任公司-SQL
中国地质环境监测院-HP LH3000
藁城市东街百货-EFS文件解密成
工商银行山东分行-AIX删除LV数
中央电视台新闻评论部-苹果分
promise乔鼎硬盘阵列数据恢复成
麒麟童文化-苹果分区无法打开,
NAS 8100服务器数据恢复成功 
解决方案
raid磁盘阵列OFFLINE后的应急方
磁盘未被格式化,是否格式化数据
误GHOST、误一键恢复灾难应急方
误删除、误格式化数据灾难应急
LINUX FSCK数据出错灾难应急方
北亚数据恢复 - 联系我们 - 关于北亚 - 友情链接 - 网站地图 - RSS聚合 
版权所有 北京北亚数据恢复中心
24小时免费咨询电话:4006-505-808 或 800-810-580
中关村部:北京市海淀区中关村大街11号E世界A座8层832B室
皂君庙部:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528室