Example of the size of the name: %.l_.fcode _ %.f_.SN%.n
File SConner..INI Section [ MODELS ] determines the rules of the reference of concrete models to the families. Selection goes on the version of the micro-code. In the standard delivery, all known to the authors versions refer in one and the same section [ U8 ]. If you want to make more detailed division into the families with the more fine adjustment the separation must be produced precisely at this level. Section [ LOGICAL ] contains the reference book of the standard models of accumulators. It is possible to supplement independently it, adding the names and the logical parameters of necessary models. Section [ GENERAL ] can contain the base tuning of utility, necessary for the normal operation with accumulators Seagate U8/.V8/.U10.
Section [ CP LIST ] contains parameter max CP, which determines the number of maximum modulus which will be preserved in the file of resources. The standard value of this key for Seagate U8 is such: Max CP=222
Nominal sections –this of the section of the description of families. The names of the sections must coincide with those, which are assigned in the section [ MODELS ].
In any of the nominal sections the following keys are possible:
CP TimeOut Is determined the maximum waiting time of the readiness of accumulator during reading CP in milisekundakh.
CP LIST Is determined the enumeration of the moduli of official region, which are subject to readout. The fact is that the turning to certain of the moduli, causes the "hovering" of nakopitel 4 and is necessary to exclude them from the work. For the savings of place, can be assigned both the concrete moduli and ranges. Thus, naprime r, record by 1,2,3,4 indicates: "to place in the list moduli with numbers 1, 2, 3 and 4", but record by 1-4 indicates the same. But record by 1-4,10-20 indicates "to place in the list moduli with the numbers from 1 to 4, and also from 10 to 20 inclusively".
The standard value of this key for Seagate U8/.V8/.U10 is such: CP LIST = 0-24,221 Electronics General information Accumulators Seagate U8, Seagate V8 and Seagate U10 are distinguished by pays of elektroni - Ci. The pays of accumulators Seagate U8 and U10 are distinguished between themselves extremely insignificantly and they can be interchanged. Moreover, are noted the cases of entering from the plant of accumulators U10, on which were established the pays of older sample –from Seagate U8. Pr and the replacement of pay U10 to the pay from U8 should be only altered the microprogram of nakopitel 4 into flesh - PZU. The pay of accumulator Seagate V8 differs from accumulators Seagate U8/10 in terms of the microcircuit of servodekodera: on accumulators U8/.U10 is established servodekoder of production ST, while on V8 – production NEC. In view of this pays V8 and U8/.U10 are incompatible between themselves. 上一篇:HRT的Seagate Drives U4英文说明书 下一篇:HRT的Seagate Drives U6英文说明书 |