您当前的位置:首页>>技术中心>>HRT技术文章>>正文
 
HRT的Seagate Drives U6英文说明书
作者: 来源: 日期:2006-3-26 1:51:06  点击次数:

Because of this, in the utilities the testing is led via access to surface  only  along the logical coordinates of the sectors, whose conversion into the the physical koo of rdinaty achieves accumulator itself.

Sequence of testing the surface
For accumulators  U6  formatting logical surface is the record into the formatiruyemuyu region of any data through  Ata- interface (on the logical coordinates).
Imperatively one should conduct formatting accumulator, also, before beginning, strictly, the search for defects. The preliminary formatting of surface is necessary for the exception of interpr of etatsii as  the physical defects  of sectors with the incorrect  Comte by the rolled sum  and the sectors with the incorrect  number of sector  in his title.
For accelerating formatting  entire  surface we advise to use a point of menu  Actions - > Quick Clear.
Point  "Quick Clear"  in the utility is realized with the aid of  Ata- command  Security Erase Unit;  therefore during the random interruption of the rapid erasure of accumulator will have to remove the password established by utility from it.

The possibility of checking the surface on the logical coordinates only requires the required formatting of surface after the sequential concealment of defects in  P -.list.  Otherwise, from the now concealed into  P -.list  defect to the end of the physical track, on the coto bark the rum defect was found, for all sectors during an attempt at reading will be returned error  UNC.  This by the noncoincidence of the numbers of these sectors in their titles with the numbers, coto bark rye caused expects the translator of accumulator. Formatting will lead to the copying Nome ditch in the titles at the correct values.

Is recommended the producing of testing pove of rkhnosti of that newly entered of nakopitel 4 in the following sequence:
12)  Test->.Bufer – testing the data bus  Ata- interface.
1 3)  Actions - > Quick Clear – for eliminating  Unc- the errors, not caused by the physical surface damage.
14) Defectlist - > G it -.list - > Clear on disk – the removal of the acquired defects (in the process of operation).
15) Test - > Verify forward(.reverse) -  the rough testing of surface by verification. Obtained defects during  the tests  not to hide,  but to accumulate in the list.
16) Recovery -  concealment of the obtained defects  by united list  into  P -.list.
17) Test - > Write forward – formatting surface after the concealment of defects obtained in  verify- tests.  So into each sector will be brought in its number –for the subsequent testing of the errors of transl of yatora of accumulator.
18) Test->.Read+.Check – testing surface by reading and checking the translator of accumulator.
19) Test->.Defectoscope – testing (thinner) surface with the installation of the maximum time of the response of surface.

本新闻共9页,当前在第2页  1  2  3  4  5  6  7  8  9  


上一篇:HRT的Seagate Drives U8, V8, U10英文说明书
下一篇:HRT的Seagate Drives Ux英文说明书

  北京总部: 4006-505-808
  上 海 部: 021-58358765
  深 圳 部: 0755-83692929
  浙 江 部: 13666673722
  广 州 部: 020-83821091
  重 庆 部: 023-86870422
  昆 明 部: 15987117834
  哈尔滨部: 13946167430
  其它地区: 4006-505-808

经典案例
中国石油管理局-Oracle数据库恢
中国网通-IBM EXP300磁盘阵列数
大连鸿德经贸有限责任公司-SQL
中国地质环境监测院-HP LH3000
藁城市东街百货-EFS文件解密成
工商银行山东分行-AIX删除LV数
中央电视台新闻评论部-苹果分
promise乔鼎硬盘阵列数据恢复成
麒麟童文化-苹果分区无法打开,
NAS 8100服务器数据恢复成功 
解决方案
raid磁盘阵列OFFLINE后的应急方
磁盘未被格式化,是否格式化数据
误GHOST、误一键恢复灾难应急方
误删除、误格式化数据灾难应急
LINUX FSCK数据出错灾难应急方
北亚数据恢复 - 联系我们 - 关于北亚 - 友情链接 - 网站地图 - RSS聚合 
版权所有 北京北亚数据恢复中心
24小时免费咨询电话:4006-505-808 或 800-810-580
中关村部:北京市海淀区中关村大街11号E世界A座8层832B室
皂君庙部:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528室