您当前的位置:首页>>技术中心>>HRT技术文章>>正文
 
HRT的Seagate Drives U6英文说明书
作者: 来源: 日期:2006-3-26 1:51:06  点击次数:

Therefore:
3) in the utility is provided the automatic conversion of the check sum (for those moduli, by which this it is necessary) during an attempt at their record;
4) after the record of modulus should be it considered conversely, in order to verify was accepted accumulator your changes.
Work with the moduli of the accumulator
For the access to the moduli of official region select the point of menu  Service - > CP Operations.  The dialogue of work with the configurative pages is in detail described in the general management on complex  HRT.
One should especially accurately relate to the moduli with signature  SYS1  and  SYS2, since these moduli contain the most important adaptive tuning of nakopitel 4, introduced there in the plant  testing. With their loss the accumulator can ispor of tit's 4 forever!
Work defect - by sheet  the general information
Dialogue defect - sheet has the following points:
P+.g-.list – reflects the mixed defect - the sheet  (P -.list, G -.list  and  Track-.list  odnov belt)
P -.list – plant (sectorial) defect - sheet.
G -.list – the sheet of the acquired defects. In it are placed the defects, discovered in so on to otsesse of the operation of accumulator.
Track – track defect - sheet.
Logical – window for adding the defects in the logical coordinates.  You can either introduce the defects through this dialogue or import them from the file, sfor mi rovannogo by any program of testing logical surface. Then it is necessary to cause by the right knob of the mouse of menu defect - sheet and to harvest point  "Upload".  Defects will fall in  P -.list.
One should remember that after the addition of defects into  P -.list  it is necessary to produce formatting surface.
 
Special features defect - sheet of accumulators  Seagate U6
The defect - the sheet of accumulators Seagate U6  should be carried  to the special features:
5) the placement of defects in the utility is possible only by way of the indication of their logical coordinates;
6) the procedure of pomeshcheni of 4 defects in  P -.list  is sufficiently prolonged, since it requires the subsequent conversion of the translator of accumulator. The time of conversion depends on general stake - VA of defects in  P -.list  and can range from  7  seconds to  6  minutes. This is caused by the low speed by the utilized in the disk OEVM and large complexity of the algorithm of the addition of defects.
7)  the addition even of one defect requires the required dual of perezag of ruzki of accumulator. Utility carries out reloadings automatically.

During the random interruption of the procedure of the concealment of defects should be carried out the actions described in the division "debugging ".

In other respects, it should be noted that because of the impossibility of obtaining by the user of information correspondence Phiz. the coordinates of defect its  LBA,  direct introduction of defects with the physical coordinates into the sheets is hindered. Therefore the addition of defects from the dialogue defect - sheet to window  P  and  G of sheets is blocked. Given dialogues are left as informative, for obtaining the information about the state of sheets at the current moment.

本新闻共9页,当前在第6页  1  2  3  4  5  6  7  8  9  


上一篇:HRT的Seagate Drives U8, V8, U10英文说明书
下一篇:HRT的Seagate Drives Ux英文说明书

  北京总部: 4006-505-808
  上 海 部: 021-58358765
  深 圳 部: 0755-83692929
  浙 江 部: 13666673722
  广 州 部: 020-83821091
  重 庆 部: 023-86870422
  昆 明 部: 15987117834
  哈尔滨部: 13946167430
  其它地区: 4006-505-808

经典案例
中国石油管理局-Oracle数据库恢
中国网通-IBM EXP300磁盘阵列数
大连鸿德经贸有限责任公司-SQL
中国地质环境监测院-HP LH3000
藁城市东街百货-EFS文件解密成
工商银行山东分行-AIX删除LV数
中央电视台新闻评论部-苹果分
promise乔鼎硬盘阵列数据恢复成
麒麟童文化-苹果分区无法打开,
NAS 8100服务器数据恢复成功 
解决方案
raid磁盘阵列OFFLINE后的应急方
磁盘未被格式化,是否格式化数据
误GHOST、误一键恢复灾难应急方
误删除、误格式化数据灾难应急
LINUX FSCK数据出错灾难应急方
北亚数据恢复 - 联系我们 - 关于北亚 - 友情链接 - 网站地图 - RSS聚合 
版权所有 北京北亚数据恢复中心
24小时免费咨询电话:4006-505-808 或 800-810-580
中关村部:北京市海淀区中关村大街11号E世界A座8层832B室
皂君庙部:北京市海淀区学院南路68号吉安大厦C座(汇智楼)528室